Mfg Part Number: 5907286 | Manufacturer: Transformer Technicians Inc | NSN : 5950-01-346-9706 |
NIIN : 013469706 | Item Name : transformer power | CAGE Code : 96253 |
FSC : 5950 Coils and Transformers |
When you need NSN parts bolstered by rapid lead times and cost savings along all avenues, call on Aviation Parts Distributor to get the job done. Here, entities can request a quote for any 5907286 (Transformer Power) product of interest associated with the NSN 5950-01-346-9706, by Transformer Technicians Inc, those of which are housed on our online database of over 2 billion new, used, obsolete, and hard-to-find NSN components. Readily available for purchase through the submission of an RFQ form as provided on this page, entities may request a quote for their comparisons on desired NSN items with the part number 5907286 that are of interest. Upon receiving a completed RFQ form, our account representatives will utilize their market prowess to provide you with a solution that satisfies your part needs in just 15 minutes or less.
Operating as an FAA AC 00-56B, AS9120B, and ISO 9001:2015 accredited enterprise, our customers can trust in the quality of our processes. As the only independent distributor with a NO CHINA SOURCING pledge, we guarantee the authenticity of all purchased parts, meaning that all items are shipped alongside their manufacturer trace documentation or qualifying certifications, as applicable. With our global supply chain stretching across the United States, customers can experience little operational downtime when requesting customized shipping on 5907286 (5950-01-346-9706) items with the CAGE Code 96253, by Transformer Technicians Inc.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-346-9706 Item Description: Transformer Power | 5950 | 013469706 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5907286 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.440 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.550 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BFMF | COOLING METHOD | SELF-COOLED |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 13 WIRE LEAD |
ABMK | OVERALL WIDTH | 2.062 INCHES MINIMUM AND 2.680 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM SINGLE GROUP AND 0.158 INCHES MAXIMUM SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 99167-5907286 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRMJ | WINDING POWER RATING | 11.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 18.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |